DQMH Consortium Toolkits Discussions

cancel
Showing results for 
Search instead for 
Did you mean: 

Request VI Template?

Solved!
Go to solution

Is the request VI generated from a clean block diagram or based on some template? If based on a template, can I replace it? If so, where can I find it?

Michał Bieńkowski
CLA, CTA, CPI

  1. Did someone devote their time to help solve your problem? Appreciate it and give kudos.
  2. Problem solved? Accept as a solution so that others can find it faster in the future.
  3. Contribute to the development of TestStand by voting on the TestStand Idea Exchange.
0 Kudos
Message 1 of 6
(223 Views)
Solution
Accepted by topic author bienieck

If you go to this folder:

 

<National Instruments>\LabVIEW 20XX\project\Delacor\DQMH\_DQMH New Event\templates

 

You will find some templates. The scripting tools expect a lot of little details to be there, like the names of certain structures. It may be able to tolerate a very small modification, but I wouldn't touch it!

Message 2 of 6
(206 Views)

I didn’t want to modify the logic, only the layout of the diagram, so that after running the script for generation, the code would be less chaotic. Maybe something is wrong with me, but knowing how awkward these autogenerated diagrams are, I just can’t sleep.

 

However, I see that the templates have too few "stubs" to achieve what I want without modifying the generator.

 

It seems I’m left with the following options: a suggestion on the Idea Exchange, manual fixes, or sleepless nights (the last two options might be combined).

Michał Bieńkowski
CLA, CTA, CPI

  1. Did someone devote their time to help solve your problem? Appreciate it and give kudos.
  2. Problem solved? Accept as a solution so that others can find it faster in the future.
  3. Contribute to the development of TestStand by voting on the TestStand Idea Exchange.
0 Kudos
Message 3 of 6
(183 Views)

You should not ever be looking at the block diagram of a request VI. We will most probably not spend any energy tidying it.

 

That being said, please create a feature request - the number of kudos might make us change our minds 🙂




DSH Pragmatic Software Development Workshops (Fab, Steve, Brian and me)
Release Automation Tools for LabVIEW (CI/CD integration with LabVIEW)
HSE Discord Server (Discuss our free and commercial tools and services)
DQMH® (Developer Experience that makes you smile )


Message 4 of 6
(173 Views)

Yes, I know, but it's like the zoom feature in LabVIEW. You supposedly shouldn't need it, but NI added it anyway because it was a pain point for someone. Here is my idea.

Michał Bieńkowski
CLA, CTA, CPI

  1. Did someone devote their time to help solve your problem? Appreciate it and give kudos.
  2. Problem solved? Accept as a solution so that others can find it faster in the future.
  3. Contribute to the development of TestStand by voting on the TestStand Idea Exchange.
0 Kudos
Message 5 of 6
(162 Views)

I truly appreciate your feedback and we're grateful that you take time out of your day to create feature requests for your ideas. Thank you, Mike!




DSH Pragmatic Software Development Workshops (Fab, Steve, Brian and me)
Release Automation Tools for LabVIEW (CI/CD integration with LabVIEW)
HSE Discord Server (Discuss our free and commercial tools and services)
DQMH® (Developer Experience that makes you smile )


Message 6 of 6
(156 Views)