Bonenkar Implants Pvt. Ltd.

Bonenkar Implants Pvt. Ltd.

Medical Equipment Manufacturing

Ahmedabad, Gujarat 45 followers

Trust in Every Turn

About us

Bonenkar Basal Dental implants can replace missing teeth and restore masticatory function. Advantages are like only one surgery required, teeth placement within 2 days and surgery and implant cost is drastically reduced. our Basal Implant’s initial stability is 40 % higher comparing to any other single thread profile Basal Implant (testing done in NABL approved Lab).

Website
www.bonenkar.com
Industry
Medical Equipment Manufacturing
Company size
51-200 employees
Headquarters
Ahmedabad, Gujarat
Type
Privately Held
Founded
2019

Locations

  • Primary

    55-56-57, Silver Industrial estate. Opp. HOF furniture,,

    Nr. Nova Cil petrochemical, Moriya,

    Ahmedabad, Gujarat 382213, IN

    Get directions

Employees at Bonenkar Implants Pvt. Ltd.

Updates

  • Basal Implants 101: an introductory workshop for aspiring experts. Skillfully guided by Dr. Gagandeep Gauba. A glimpse of Session 1 tabletop demonstration of lingual cortical engagement using a mandible bone model. You can join us for a complimentary webinar. An engaging webinar designed for both newcomers and professionals looking to deepen their expertise. Don't miss this unique opportunity to learn from the best, enhance your skills, and connect with a community of aspiring experts. You can just register now to transform your potential into mastery. Join on 2nd June at 10:00 am: https://lnkd.in/dEi7Cz4g

    View profile for Jayendra Diwan, graphic

    Managing Director at Bonenkar Implants Private Limited & Mobilimb Prosthesis Pvt Ltd.

    Basal Implants 101: an introductory workshop for aspiring experts. Skillfully guided by Dr. Gagandeep Gauba. A glimpse of Session 1 tabletop demonstration of lingual cortical engagement using a mandible bone model. You can join us for a complimentary webinar. An engaging webinar designed for both newcomers and professionals looking to deepen their expertise. Don't miss this unique opportunity to learn from the best, enhance your skills, and connect with a community of aspiring experts. You can just register now to transform your potential into mastery. Join on 2nd June at 10:00 am: https://lnkd.in/dhP6XWtq

  • BONENKAR Titanium (TI 6AL 4V) Orthodontic Mini Implants. (TRUST IN EVERY TURN) SPECIAL OFFER | GET YOUR Free DEMO of Orthodontic screw. Experience our superior implants firsthand.   Contact us now for No-Cost, No-Obligation demo kit and See the difference for yourself.   +91 97131 89283 +91 80543 43801 +91 79749 22345

    • No alternative text description for this image
  • Implant Placement in Cases of Minimal Bone below the Maxillary Sinus Engaging the Lateral Nasal Wall When the bone below the maxillary sinus is insufficient, implants cannot be placed conventionally. In such cases, the implant can be anchored in the lateral nasal wall. Suitable implant choices are Basal Tornado or Basal Varioss. Engaging the Palatal Bone Another technique involves engaging the palatal bone by initiating the osteotomy laterally and targeting the palatal bone directly. The preferred implant for this technique is the Basal Classic due to its low-profile, single-thread design. This implant minimizes torque and is ideal for narrow, high-density bone to prevent fractures.

  • Accessory Implant Sites for Load Dispersion Key Points: ·        Accessory Sites: Lateral nasal wall, palatal bone, or mid-palatal engagement. ·        Purpose: o   Reduce the jumping distance between implants, especially in cases of sinus pneumatization. o   Prevent prosthesis fractures due to high inter-implant distance. ·        Note: o   These are load-dispersing, not load-bearing sites. o   Not suitable as standalone implants.

  • Basal Implants for Pterygoid Area Implant Choices: 1.      Tornado Implant: o   Smooth surface compressive implant. o   Allows perforation of the second cortex. o   Designed specifically for the pterygoid area. o   Requires only one implant. 2.      VarioS Implant: o   Requires two implants (double pterygoid technique). o   Not recommended as a single implant solution.

  • Hands-on basal and compressive implant training at your clinic (India / International). Free Demo: Receive implants, drills, and realistic bone models at no cost. Check if our training system meets your requirements. If it doesn’t, no worries! Our courier will visit in two days to collect all the items. If the system aligns, we can proceed with further discussions             There is no obligation to purchase anything and no obligation for training.               ·        Training System 1.     Practice 20 unique drilling protocols and place 10 implants using bone models designed to replicate human bone anatomy, featuring a hard cortical top layer and a soft cancellous core. 2.     Expert Guidance: Dr. Gagandeep Gauba will personally train you through interactive video conferencing, ensuring expert instruction and real-time support. ·        Total Cost - 9000 INR (India) / 150 USD (International). 1. 5 Drills (1 pilot, 2 twist and 2 conical drills), Implant Driver, 5 Implants for Practice – Available on a Returnable Basis 2. Maxilla and mandible Bone Model - 4000 INR (India) / 80 USD (International). 3. Online Live Training - 20 unique drilling protocols and 10 implants placement (No theory only Practical) - 5000 INR (India) / 70 USD (International) . 4. EMI Option available. 5. If this training doesn’t transform your practice, we’ll bear the entire Cost.   +91 97131 89283 +91 80543 43801 +91 79749 22345

    • No alternative text description for this image
  • Design of Varioss Basal Implants 1. Thread Engagement ·        Cortical Threads: Engage the basal bone for anchorage. ·        Cancellous Threads: Engage cancellous bone through compression. 2. Passive Shaft Design ·        The shaft is thread-free and does not engage the first cortex. ·        Ensures the first cortex remains passive and unaffected. 3. Prevention of Peri-Implantitis ·        Avoiding threads in the first cortex minimizes the risk of resorption and peri-implantitis. ·        The smooth shaft design prevents thread exposure, enhancing long-term implant stability.

  • Features and Advantages of Varioss Implant 1. Dual Thread Design Cortical Threads: Located at the apex, these threads actively engage the nasal cortical floor. Compressive Threads: Positioned behind the cortical threads, designed to compress and stabilize in cancellous bone. 2. Bifocal Anchorage The implant utilizes both the nasal cortical floor and spongy cancellous bone for anchorage. Ensures high torque stability in the cancellous bone. 3. Ideal for Maxillary Anterior Region The basal Varioss implant is preferred in this region due to its dual-thread design and compressive nature, providing superior stability.

Similar pages