KPipe have large stocks of 4inch and 6inch sewer pipes and fittings, on the ground, available for collection or delivery. Please get in touch for a quote: ☎01942 247000 📧rachael@kpipe.co.uk
K Pipe Ltd’s Post
More Relevant Posts
-
Don’t let small cracks lead to big problems. Beton Perma offers efficient crack repairs that restore the integrity and performance of your floors. Deepak Bohidar #FloorRepair #BetonPerma #ConcreteSolutions #CrackRestoration #FloorDurability #IndustrialFlooring #LongLastingFloors #ConcreteMaintenance #RepairAndRestore #ProtectYourFloors
To view or add a comment, sign in
-
** Relation between cementitious content in concrete and other parameters ** As the cementitious content in the concrete mix increases, the following parameters are expected to increase: 1- Concrete compressive strength 2- Concrete durability 3- Probability of drying shrinkage and related cracks 4- Generation of heat 5- Amount of water needed for hydration 6- Cost 😉 And the following parameters will be decreased as cementitious content increases: 1- Bleeding of concrete 2- Permeability of concrete
To view or add a comment, sign in
-
SealGuardII is engineered to provide an effective, long-lasting solution to leaks and water infiltration. Used to control high flowing water leaks. SealGuard II is injected to seep deep into cracks and crevices ensuring comprehensive coverage and protection against leaks at their source. SealGuard II can be used in very fast water flow rates - in flows of up to 3 litres per second (189 litres/42 gallons per minute), stopping leaks easily and permanently at a fraction of the cost of traditional methods; with the versatility to be used in manholes, culverts, bunds, or any brick or concrete structure which needs to be dry. To see how SealGuardII works, you can check out the full video on YouTube and click the link. #SealGuardII #s1euk #S1E #SealGuardII #trenchlesstechnology #drainagesolutions #piperepair #sealant #sewer #waterleaks #waterinfiltration #FutureOfConstruction #InfrastructureInnovation #SustainableConstruction https://lnkd.in/eV-Gs5f8
Sewer Pump Station Water Infiltration Repair with SealGuard II Grout
https://www.youtube.com/
To view or add a comment, sign in
-
Complex repairs, simplified solutions. We recently cured the pain of a concrete slurry pump for a Local Pipe Manufacturer, ensuring optimal performance. At Velocity, We cure Pump Pain, #pumprepair #industrialmaintenance #velocitypumpandcontrols #curepumppain
To view or add a comment, sign in
-
Phenolic section lagging, plain Ali cladding with stainless steel banding on chilled water pipework. #thermalinsulation #thermalinsulationengineer
To view or add a comment, sign in
-
The temperature of the mix Asphalt at the time of laying shall not be less than 120°C, minimum
To view or add a comment, sign in
-
Prepare for a Solid Foundation: A Guide to Components Discover the importance of proper preparation before pouring cement. Learn about handling moisture, installing vapor barriers, reinforcing with rebar, and ensuring plumbing is in place. Get ready for a smooth and durable cement foundation. #CementPouring #ConstructionTips #FoundationPreparation #MoistureManagement #ReinforcingConcrete #PlumbingInstallation #BuildingBasics #DIYProjects #ConstructionGuides #HomeImprovement
To view or add a comment, sign in
-
quick check of formwork of retaining wall and circular column of water storage tank in King Salman Park, pouring Height of circular column is 10 m
To view or add a comment, sign in
235 followers